Single Phase Online UPS offered by be servo system, the renowned brand, is designed and manufactured keeping in mind diverse specifications of different electronic equipment’s and devices. These UPS provides complete power backup for few minutes so that you can save your important data or can turn of the machine. These are very easy to connect with your electric devices or equipment’s and don’t lead to high electricity consumption for charging. To meet the different requirements of the customers, we manufacture the UPS in different models and offer them at affordable prices. Single phase online UPS is generally suitable for Diamond laser cutting machine, Computerized Sequence Embroidery Machines, Local area networks, industrial PLC and emergency & security devices, Computer & Microprocessor based industrial equipment like bank cash dispensers, telecommunication devices, Equipment such as FAX, EPABX etc.
Technical Specifications
Capacity |
600 VA
– 3 kva |
Model/Make |
Branded |
Technology |
SPWM,
IGBT/MOSFET (for more than 72 DC volt IGBT preferred) |
Input input
Voltage |
230 V
AC, Single phase |
Input
Voltage Range |
160 V
AC TO 270 V AC |
Input
Frequency Range |
45 TO
55 Hz |
Input
Over Voltage Protection |
280 V
AC |
Input
Under Voltage Protection |
155 V
AC |
Over
Voltage Cut Off |
Should
be offered externally |
Output
Voltage |
230 V
AC Single Phase +-1% |
Frequency |
50 HZ
+-1% |
Load
Power Factor |
0.8 Lag
to Unity |
Isolation |
Output
load be isolated through a transformer of same rating |
Output
Over Voltage Protection |
245 V
AC Single Phase |
Output
Under Voltage Protection |
210 V
AC Single Phase |
Over
Load Capacity |
125% of
rated load for 60 sec |
Short
Circuit Protection |
Soft
shut down should occur without blowing any fuse |
Isolation |
Manual
Bypass Switch Should be provided of same rating |
Indicators |
1) Over
Temperature- Required |
Static
Switch |
Automatic
Bi-directional should take care of 100% uninterrupted transfer of load from
UPS Transfer Time 85 % Inverter Efficiency > 90 % |
Metering |
Separate/Single
Digital Meter |
Battery
Period of Backup |
Sealed
Maintenance Free Lead Acid Battery of >= 12 V each of uniform AH rating |
DC Bus
Ripple |
2 Hr.
with 100% load < 1% |
Battery
Recharge Time |
From
Fully Discharge Condition To 100% Charged Condition< 12 hrs. Total Dc Bus
Banks SINGLE |
Battery
Housing |
Closed
housing with suitable lockers |
Auditable
Alarm for Following Conditions |
•
Battery Low |
Environmental |
•
Operating Temperature < 45 Deg C |